Although efficacies and proportions of tympanoplasty performed via endoscopic ear surgery (EES) have gradually introduced, it remains unclear whether total EES is a good alternative to microscopic ear surgery (MES). Herein, we aimed to compare therapeutic effects of EES and MES in patients receiving tympanoplasty or myringoplasty. A search of MEDLINE, PubMed, and Embase databases was conducted to compare the efficacies of EES and MES. Two investigators independently reviewed all studies and extracted data with a standardized form. We assessed risk of bias and calculated pooled odds ratio (OR) estimates with a 95% confidence interval (CI). Thirteen studies (607 EES patients and 678 MES patients) met inclusion criteria for quantitative meta-analysis. In pooled analysis, those who undergo EES have 0.99 times the OR of graft success compared to those with MES (95% CI, 0.84 to 1.16; P=0.894). In qualitative analysis, comparable hearing improvement was observed between the two groups, despite inconsistent audiometric evaluation. The air-bone gaps (ABGs) improved 2.02 dB less in EES than in MES (mean difference of improvements of ABGs, 2.02; 95% CI, –3.84 to –0.20; P=0.029); however, substantial heterogeneity and publication bias limited the integrity of this analysis. Further, EES significantly decreased canalplasty rate, wound complications, and operation time, compared to MES. Moreover, patients receiving EES reported higher cosmetic satisfaction than patients receiving MES. EES can be a good alternative to MES in terms of comparable graft success rate and hearing outcomes in patients receiving tympanoplasty or myringoplasty. Moreover, EES was less invasive, resulting in higher cosmetic satisfaction, reduced morbidity, and shorter operation time. Our results may affect decision-making and outcome prediction in cases of EES; however, confirmation is needed to clarify potential bias.

INTRODUCTION

Tympanic membrane (TM) perforation is a common surgical indication in an otolaryngology practice; it can be managed by tympanoplasty or myringoplasty [1]. Repair of TM perforation via the microscopic ear surgery (MES) is traditionally preferred worldwide, with success rates ranging from 83% to 100% [2-4]. Since the endoscope was introduced for middle ear surgery in the 1970s, assisted or total endoscopic ear surgery (EES) has been introduced to evaluate the degree of disease and to resolve middle ear pathologies [5,6]. Although the transcanal approach using endoscope may be restricted by single-handed surgery, a loss of depth perception, and a steeper learning curve [7], endoscopy is characterized by panoramic, wide angle, and magnified views that can overcome most disadvantages of a microscope, providing effective access to the middle ear with no requirement for postauricular incision and canalplasty [8].
Recently, EES has demonstrated comparable treatment outcomes of MES with respect to TM closure rates, as well as hearing improvement [9-20]. Furthermore, the application of EES for tympanoplasty or myringoplasty has been extended to challenging cases, such as those involving anterior TM perforation and pediatric patients exhibiting a narrow ear canal [21]. A previous systematic review and meta-analysis demonstrated comparable TM closure rates and hearing outcomes between endoscopic and microscopic tympanoplasty; however, the results were limited by a lack of enrolled studies and potential bias that may have affected the integrity of the study [22]. Furthermore, the strength of bias leading to small-study effects has not yet been elucidated. Notably, a growing body of evidence regarding comparative efficacies between the two operative tools has been reported after publication of the previous systematic review and meta-analysis.
Although efficacies and proportions of tympanoplasty performed via endoscopy have gradually increased due to new technologies (e.g., high-definition cameras, 3-mm endoscope, and curved burrs with a protective shaft) [11], it remains unclear whether total EES is a good alternative to MES for repair of TM perforation. Herein, we aimed to explore the therapeutic effects, according to surgical tool, by a systematic review and meta-analysis; further, we aimed to meticulously evaluate the integrity of quantitative analysis.

MATERIALS AND METHODS

This systematic review was developed and performed in accordance with recommendations from the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklists. A PRISMA flow diagram was used to describe the flow of information throughout various phases of the systematic review [23]. This study utilized quantitative methods to examine reasons for variation in treatment outcomes.

Search strategy

Two of the authors (SYL and YS) independently searched MEDLINE, PubMed, and Embase databases for articles published from database inception through June 30, 2018, for all available studies reporting comparison of the efficacies of tympanoplasty or myringoplasty via EES and MES. Based on the search syntax adopted by a previous systematic review and meta-analysis [22], this study employed the following search keywords. The search keyword for the PubMed database was “(endoscop*tympanoplast*[Title/Abstract] OR endoscop*myringoplasty*[Title/Abstract])”; the search keyword for the Embase database was “(endoscop*tympanoplast*:ab.ti OR endoscop*tympanoplast*:ab,ti)”; the search keyword for the MEDLINE Ovid database, “(endoscop*tympanoplast* OR endoscop*myringoplast*).ti.”

Study selection

All retrieved articles were independently screened by two authors (SYL and YS) based on titles and abstracts by using the search strategy. Full texts of eligible articles were subsequently evaluated based on inclusion and exclusion criteria (Fig. 1). Inclusion criteria for the present study were as follows: (1) report of a comparison with at least one postoperative outcome including graft success rates, audiometric results, canalplasty rate, and cosmetic results; (2) original articles from peer-reviewed scientific journals published in English. The following types of publications were excluded: (1) animal studies, in vitro studies, review articles, and case reports; (2) publications where original articles were inaccessible (e.g., only abstracts were available) and/or incomplete data were provided; (3) duplicate publications; (4) studies with duplicate data (e.g., a mixture of endoscope-assisted ear surgery and total EES). Thus, the EES group included only patients who received total EES. Unfortunately, we were unable to contact study authors to obtain additional information and further studies.

Data extraction

Two authors reviewed all relevant studies and independently extracted data; any discrepancies were resolved by consensus between the two authors. For meta-analysis, the following information was retrieved: author, year of publication, study design, number of patients, and treatment outcomes. Analysis of pooled proportions was performed; cases with missing or incomplete information were excluded. For treatment outcomes, weighted proportions and their 95% confidence intervals (CIs) were calculated.

Statistical analysis

In this study, estimated pooled odds ratio (OR) and 95% CIs were calculated by using fixed-effects or random-effects models; selection of random-effects or fixed-effects models was based on a conceptual understanding of the presence of population effects within enrolled studies, rather than statistical results of homogeneity tests. We calculated the I2 statistic to evaluate rates of heterogeneity across studies. If an I2 value of >50% and a P-value of <0.10 were indicated, we classified the heterogeneity of the effect size as substantial [25]. In cases of substantial heterogeneity, the presence of small-study effects, including publication bias, was evaluated; a subsequent trim-and-fill method or sensitivity analysis was used to verify the integrity of the quantitative analysis results. Potential publication bias was examined in analyses involving more than three studies by using a funnel plot. All statistical analyses were performed by using the software package R ver. 3.3.2 (The R Foundation, Vienna, Austria).

RESULTS

Characteristics of studies included in the meta-analysis

A flow diagram including initial identification, screening, eligibility, and inclusion of studies is shown in Fig. 1. Eleven articles met the initial screening criteria based on title and abstract reviews. After evaluating full-length articles, one study was excluded because it included patients who underwent endoscopy as an adjuvant to microscopic tympanoplasty. Finally, 13 studies were included in the meta-analysis: four randomized controlled trials, four prospective, and five restrospective case-controlled studies (Table 1). A total of 1,285 patients served as subjects in the meta-analysis: 607 received EES and 678 received MES. While all subjects receiving EES were performed by the transcanal approach, those receiving MES were performed by the retroauricular (568 out of 678, 87.7%) or endaural approach (80 out of 678, 12.3%). The enrolled studies were conducted between 2001 and 2017; the age of patients ranged from 2 to 82 years. Three of 13 studies only included pediatric patients (cutoff value, 18 years).

Graft success rate

All studies included data regarding postoperative graft success rates. In the pooled analysis (Fig. 2A), those receiving EES have 0.99 times the OR of graft success compared to those receiving MES without statistical significance (95% CI, 0.84 to 1.16; P= 0.894). In addition, no heterogeneity or publication bias were found (Fig. 2B).

Hearing outcomes: air-bone gap

Table 2 shows a qualitative analysis of the hearing outcomes of each study. Despite inconsistent audiometric evaluation among the studies, most demonstrated comparable hearing improvement between EES and MES. Twelve of 13 studies exhibited postoperative hearing outcomes; five studies demonstrating mean and standard deviations of air-bone gaps (ABGs) were available for quantitative meta-analysis. In the pooled analysis with the random-effects model (Fig. 3A), the ABGs improved 2.02 dB less in EES than that in MES (mean difference of improvements of ABGs, 2.02; 95% CI, –3.84 to –0.20; P=0.029). However, a substantial amount of heterogeneity (I2=63.8%, P= 0.026) and publication bias were found (Fig. 3B). After adjustment of the trim-and-fill method, the mean difference of improvements of ABGs was –2.42 (95% CI, –4.18 to –0.67; P= 0.007) (Fig. 3C), indicating that small-study effects did not impact hearing improvement.

Canalplasty rate

Six studies addressed the comparison of canalplasty outcomes, comprising a total of 581 patients (290 patients in EES; 291 patients in MES). For canalplasty rate, it was defined in a binary fashion. In the pooled analysis (Fig. 4A), those receiving EES have 0.09 times the OR of canalplasty rate compared to those receiving MES (95% CI, 0.02 to 0.32; P<0.001). In addition, no heterogeneity or publication bias were found (Fig. 4B).

Operation time

Nine studies reported operation time according to operative tool. The operation time for EES seemed to be shorter than for MES; however, data were only available from four studies (183 patients receiving EES; 184 patients receiving MES) regarding mean and standard deviation for quantitative analysis. In the pooled analysis (Fig. 5A), the operation time for EES was significantly shorter than for MES (mean difference of operation time, 37.99 minutes; 95% CI, 2.76 to 73.21; P=0.035). However, a substantial amount of heterogeneity (I2=99.6%, P<0.001) and publication bias were found. In a sensitivity analysis, after excluding the study by Plodpai and Paje [10] that used the overlay technique, the mean difference of operation time was reduced to 24.02 minutes (95% CI, 13.62 to 34.43; P<0.001) (Fig. 5B).

Cosmetic results

Four studies comprising 80 patients in total evaluated and compared subjective cosmetic results according to poor, satisfactory, and excellent. For cosmetic satisfaction rate in this study, the number of patients rated the cosmetic results as satisfactory or excellent were calculated. In the pooled analysis (Fig. 6A), those receiving EES have 26.94 times the OR of cosmetic satisfaction rate compared to those receiving MES (95% CI, 6.26 to 115.86; P< 0.001).

Postoperative complication rate

Various postoperative complications were retrieved from enrolled studies. We quantitatively analyzed the incidence of postoperative complications, with a particular focus on wound problems, epithelial cysts, and wet ear. Data regarding wound problems were available from three studies; pooled analysis demonstrated that patients receiving EES had a significantly lower OR of wound problems than patients receiving MES (OR, 0.17; 95% CI, 0.03 to 1.00; P<0.001). However, there was no significant difference in terms of epithelial cysts from three studies (OR, 0.58; 95% CI, 0.22 to 1.50; P=0.249) and wet ear from two studies (OR, 1.00; 95% CI, 0.26 to 3.78; P=0.621), irrespective of operative tool (Fig. 6B).

Quality assessment and publication bias

We assessed the risk of bias of randomized controlled studies included in the quantitative meta-analysis based on the Cochrane Collaboration tool (Supplementary Table 1). For prospective and retrospective studies, we examined internal validity by using the Newcastle-Ottawa Scale criteria (Supplementary Table 2). In analyses involving more than three studies, publication bias was found in hearing outcomes (P<0.001 for hearing outcomes), except for graft success rate and canalplasty rate. Funnel plots for publication bias with respect to hearing outcomes presented noticeable asymmetry.

DISCUSSION

In this study, surgical approach-related therapeutic effects were compared with different perspectives through a systematic review and meta-analysis. Graft success rate and hearing improvements of EES and MES were comparable, which supported previous studies suggesting that EES for tympanoplasty or myringoplasty can be a good alternative to MES. Although an slight improvement in ABGs of MES was elicited compared to ABGs of EES, this result seems not clinically meaningful considering small-study effects related to potential publication bias. Additionally, EES may be superior to MES in terms of canalplasty rate, operation time, cosmetic results, and post-treatment complications.

Comparable effects with respect to graft success rates and hearing outcomes

Although a previous meta-analysis regarding a comparison of surgical approach-related graft success rates and hearing outcomes was introduced thus [22], the results were limited by a lack of enrolled studies and subsequent small-study effects that lead to potential bias. Considering that a growing body of evidence on implications of EES has been increased recently, clinical effectiveness between two operative techniques remains to be re-established.
The present study comprised of relatively large patients revealed a comparable graft success rate between endoscopic and microscopic approaches based on the meta-analysis. In qualitative analysis, the graft success rate via the EES ranged from 83% to 100%, which is consistent with that of the MES. Because neither significant risk differences nor publication biases were observed between the two operative tools, the estimated effect in terms of graft success rate may be unalterable. Although age, a factor previously associated with graft success rate, may restrict this result [21], our meta-analysis with a moderator showed that the graft success rate between EES and MES did not depend on age (Supplementary Fig. 1). Moreover, in our qualitative analysis of pediatric patients, the graft success rate of EES was >85%, compatible with the results of a recent meta-analysis of pediatric tympanoplasty [26]. This may be a result of a wider endoscopic surgical view, as well as innovations of endoscopic technology that enable access for tympanoplasty or myringoplasty in nearly all cases [11].
However, previous studies suggested that the comparable graft success rate is more likely associated with grafting technique, rather than surgical approach [22]. Although one of our enrolled studies performed an overlay grafting technique that led to a higher graft success rate (96.7%) and comparable overall success rate [10], our quantitative meta-analysis of graft success rates might be biased to exclusively include the underlay grafting technique. Thus, additional studies, including grafting technique randomization, are warranted to clarify graft success rate based on different approaches.
In qualitative analysis of hearing outcomes, the results consistently demonstrate comparable hearing improvement of EES and MES, despite discrepancies in hearing evaluations. Remarkable TM closure rates between EES and MES may elicit comparable hearing outcomes [22]. Notably, pooled analysis in this study revealed greater hearing improvements in MES than in EES. Potential limitations involving the one-hand technique, such as difficulty in bleeding control and light-induced thermal damage, may affect hearing improvement [27]. However, potential publication bias with a substantial amount of heterogeneity may have influenced the integrity of this analysis, suggesting that the small-study effect was validated by the trim-and-fill method. Moreover, we could not assess sub-group analysis by using a moderator, including perforation site or size and revision surgery that may impact hearing outcomes because only three studies presented data for quantitative analysis of hearing outcomes including mean and standard deviation of ABGs [28].

Advantages of EES resulting from less invasive technique

Given that the surgical view from microscopy can be limited when evaluating complex structures of the external auditory canal, such as a tortuous, stenotic ear canal and bony overhangs, the tympanic annulus could not be completely visualized in 17%–20% of patients who underwent the MES. Therefore, surgeons are likely to drill out bony overhangs to visualize the comprehensive pathology of TM or the middle ear. Partial visualization of the perforation margin, as well as canalplasty, were reported to be significantly associated with prolonged operation time [21]. In our quantitative meta-analysis, a significantly higher canalplasty rate in cases of MES was identified; however, interpretation regarding prolonged operation time awaits further confirmation due to publication bias.
Conversely, the EES is considered to be a less invasive technique that involves reduced morbidity [29]. Endoscopy, characterized by panoramic, wide angle, and magnified views, enhanced performance even in challenging cases, such as anterior TM perforation; hence, no additional canalplasty was required in most cases [21]. Morbidity regarding the postauricular incision appeared to impact cosmetic results [5]. In addition to a postauricular scar, auricular displacement and asymmetry of the pinna could also develop from the postauricular incision; this may yield better cosmetic outcomes for patients who received EES [9]. Similarly, a significantly lower morbidity may cause patients to choose the endoscopic approach, as they returned to normal daily activity sooner than those receiving the MES [12,13].
In this study, EES appeared to be advantageous over MES in terms of minimally invasive technique, which is crucial for clinical outcomes. Nevertheless, transcanal approach using endoscope has some limitations. The one-handed technique is likely to lose to chance of simultaneous dissection and suction maneuver, thereby limiting healthy tissue removal [30]. Given that hemostasis is essential in the setting of one-handed surgical technique, the procedure that minimizes incision and trauma can be required, which in turn would rather hinder the surgical field. A steeper learning curve is likely to be associated with significantly with the one-handed surgical technique. In addition, two-dimensional operative image of EES causes a lack of depth perception that links to potential risk of damage to the surrounding structures not included in the visual field [31]. Even though new technologies to reduce EES related disadvantages have developed [32], the appropriate application of EES, with consideration of its limitation, would be mandatory.

Future perspectives and limitations

Although this study provides comparative data regarding the efficacy of two surgical approaches with evaluation of the integrity of quantitative analysis, as well as bias analysis that affects the integrity of the results, there are some limitations that should be addressed in future studies. First, a lack of randomized control studies (four of 13) may have led to a small-study effect, which limits the integrity of the analysis. Moreover, except for graft success rate, a relatively small number of published articles were included for other quantitative meta-analyses. Given that the strength of this study might be affected by the small number of patients [33,34], studies involving a larger cohort are warranted to further support our current interpretations. Second, enrolled studies had potential biases, as shown in the risk of bias summary (Supplementary Table 1) and quality assessment by the Newcastle-Ottawa scale (Supplementary Table 2). In addition, a publication bias was observed in most risk factor analyses, except for graft success rate and canalplasty rate. Third, risk factors that influence surgical outcomes, such as age and size or site of TM perforation, were inconsistent among the included studies. Deviated outcomes are theoretically possible due to these uncontrolled factors; therefore, a large cohort with randomization must be established in a future study. Despite limited heterogeneity and bias in this study, current results may be useful for decision-making and outcome prediction in patients receiving EES. Further well-designed large cohort studies are necessary to elucidate factors related to successful treatment outcomes of EES in patients receiving tympanoplasty or myringoplasty.
Taken together, the rate of graft success and hearing outcomes of EES were comparable with those of MES for patients receiving tympanoplasty or myringoplasty. Moreover, EES, a less-invasive technique, showed better outcomes for the rate of canalplasty, cosmetic result, wound problem, and operation time. Therefore, our results may be useful for decision-making and outcome prediction in patients receiving EES; however, further confirmation is required due to limited heterogeneity and potential bias in this study.

HIGHLIGHTS

• Endoscopic ear surgery (EES) have comparable outcomes of graft success compared to microscopic ear surgery (MES).
• EES significantly decreased canalplasty rate, wound complications, and operation time compared to MES did.
• Patients receiving EES reported higher cosmetic satisfaction than patients receiving MES.
• Air-bone gap improved 2.02 dB less in EES than in MES; however, substantial heterogeneity and publication bias limited the integrity of this analysis.
• Our results may affect decision-making and outcome prediction in cases of EES, but confirmation is needed to clarify potential bias.

CONFLICT OF INTEREST

No potential conflict of interest relevant to this article was reported.

ACKNOWLEDGMENTS

This study was supported by a clinical research grant from the SMG-SNU Boramae Medical Center, Seoul, Republic of Korea.

SUPPLEMENTARY MATERIALS

Supplementary materials can be found via https://doi.org/10.21053/ceo.2018.01277.
Supplementary Table 1.
Cochrane Collaboration’s tool for assessing risk of bias.
ceo-2018-01277-suppl.pdf
Supplementary Table 2.
Newcastle-Ottawa scale of bias risk for the non-randomized studies.
ceo-2018-01277-suppl.pdf
Supplementary Fig 1.
Forest plot comparing graft success rate between endoscopic ear surgery (experimental) and microscopic ear surgery (control), according to age group (pediatric vs. adult). Events represent the number of cases with graft success. OR, odds ratio; CI, confidence interval.
ceo-2018-01277-suppl.pdf

Fig. 1.
Preferred Reporting Items for Systematic Reviews and MetaAnalyses (PRISMA) flow diagram outlining the study design. EES, endoscopic ear surgery; MES, microscopic ear surgery.
ceo-2018-01277f1.jpg
Fig. 2.
(A) Forest plot comparing graft success rate between endoscopic ear surgery (experimental) and microscopic ear surgery (control) by using OR. Events represent the number of cases with graft success. (B) Publication bias of graft success rate. OR, odds ratio; CI, confidence interval.
ceo-2018-01277f2.jpg
Fig. 3.
(A) Forest plot comparing the improvement of air-bone gaps of endoscopic ear surgery (experimental) and microscopic ear surgery (control) by using mean difference. (B) Publication bias of hearing outcomes. (C) Adjusted publication bias after trim-and-fill method. SD, standard deviation; MD, median; CI, confidence interval.
ceo-2018-01277f3.jpg
Fig. 4.
(A) Forest plot comparing the canalplasty rate of endoscopic ear surgery (experimental) and microscopic ear surgery (control) by using OR. Events represent the number of cases with canalplasty. (B) Publication bias of canalplasty rate. OR, odds ratio; CI, confidence interval.
ceo-2018-01277f4.jpg
Fig. 5.
(A) Forest plot comparing the operation time of endoscopic ear surgery (experimental) and microscopic ear surgery (control) by using mean difference. (B) Publication bias of operation time. SD, standard deviation; MD, median; CI, confidence interval.
ceo-2018-01277f5.jpg
Fig. 6.
(A) Forest plot comparing the cosmetic results of endoscopic ear surgery (EES; experimental) and microscopic ear surgery (MES; control) by using OR. Events represent the number of cases with cosmetic dissatisfaction. (B) Forest plot comparing the postoperative complications of EES and MES by using OR, with regard to wound problem, epithelial cyst, and wet ear. Events represent the number of cases with each complication. OR, odds ratio; CI, confidence interval.
ceo-2018-01277f6.jpg
Table 1.
Characteristics of 13 comparative studies between EES and MES enrolled in quantitative and qualitative analysis
Study/country Study design EES vs. MES
Comparative parameter Follow-up period
Anesthesia, grafting techniques, surgical type No. of patients Age (yr, range)
Jyothi et al. (2017) [9]/India RCT LA, underlay, EM vs. LA, underlay, R-MM (n=60) 60 (M:F=39:21) vs. 60 (M:F=26:34) 28.5 vs. 31.4 1. Graft success rate 12 mo
2. Hearing outcomes
3. Canalplasty rate
Plodpai and Paje (2017) [10]/Thailand Retrospective LA, overlay, EM vs. LA, overlay, R-MM (n=91) 90 (M:F=33:57) vs. 91 (M:F=23:68) 45.5 (36–56) vs. 46 (22–58) 1. Graft success rate 6 mo
2. Hearing outcomes
3. Canalplasty rate
4. Surgical time
5. Postoperative outcomes
James (2017) [11]/Canada Prospective GA, EM or ET vs. GA, R-MM or R-MT (n=167) 111 vs. 167 12.7 (2–18) 1. Graft success rate 12 mo
2. Postoperative outcomes
Nassif et al. (2015) [12]/Italy Retrospective GA, underlay, EM vs. GA, underlay, R-MM (n=19) or E-MM (n=4) 20 (M:F=10:12) vs. 23 (M:F=17:6) 11 (7–16) vs. 9 (5–16) 1. Graft success rate 6–108 mo
2. Hearing outcomes
3. Surgical time
Harugop et al. (2008) [13]/India RCT Underlay, EM vs. underlay, R-MM (n=45) or E-MM (n=5) 90 Under LA; 10 under GA 50 vs. 50 15–65 1. Graft success rate 6 mo
2. Hearing outcomes
3. Canalplasty rate
4. Cosmetic results
5. Surgical time
Lade et al. (2014) [14]/India RCT Underlay, EM vs. underlay R-MM (n=30) >16 yr Under LA; ≤16 yr under GA 30 (M:F=15:15) vs. 30 (M:F=13:17) 28.30 (SD, 9.39) vs. 28.30 (SD, 9.39) 1. Graft success rate 6 mo
2. Hearing outcomes
3. Canalplasty rate
4. Cosmetic result
5. Postoperative outcomes
Raj and Meher (2001) [15]/India Prospective LA, underlay, EM vs. LA, underlay, E-MM (n=20) 20 vs. 20 NA 1. Graft success rate 10 wk
2. Hearing outcomes
Lakpathi et al. (2016) [16]/India Prospective LA, underlay, EM vs. LA, underlay, R-MM (n=30) 30 (M:F=18:12) vs. 30 (M:F=22:8) 15–55 1. Graft success rate 6 mo
2. Hearing outcomes
3. Cosmetic result
4. Surgical time
5. Postoperative outcomes
Kumar et al. (2015) [17]/India Prospective LA, underlay, EM vs. LA, underlay, R-MM (n=30) 30 vs. 30 18–45 1. Graft success rate 6 mo
2. Hearing outcomes
3. Canalplasty rate
4. Cosmetic result
5. Surgical time
6. Postoperative outcomes
Dundar et al. (2014) [18]/Turkey Retrospective GA, underlay, EM vs. GA, underlay, R-MM (n=29) 32 (M:F=14:17) vs. 29 (M:F=19:10) 12.4 (10.04–14.76) vs. 11.89 (9.82–13.96) 1. Graft success rate 12 mo
2. Hearing outcomes
3. Canalplasty rate
4. Surgical time
Kaya et al. (2017) [19]/Turkey RCT GA, underlay, ET vs. GA, underlay, R-MT (n=13) 13 (M:F=6:7) vs. 13 (M:F=6:7) 36.17±3.61 (17–53) vs. 36.17±3.61 (17–53) 1. Graft success rate 6 mo
2. Hearing outcomes
3. Postoperative outcomes
4. Surgical time
Huang et al. (2016) [20]/Taiwan Retrospective GA, underlay, ET vs. GA, underlay, R-MT (n=50 ears) 47 (M:F=17:30) vs. 48 (M:F=16:32) 54.2±15.6 vs. 49.9±15.0 (13–82) 1. Graft success rate 6 mo
2. Hearing outcomes
3. Surgical time
Kuo and Wu (2017) [24]/Taiwan Retrospective GA, underlay, ET vs. GA, underlay, R-MT (n=6) or E-MT (n=51) 74 (M:F=27:47) vs. 57 (M:F=25:32) 57.49 (16–86) vs. 55.72 (15–77) 1. Graft success rate 3–12 mo
2. Hearing outcomes
3. Surgical time

EES, endoscopic ear surgery; MES, microscopic ear surgery; RCT, randomized controlled trial; LA, local anesthesia; EM, endoscopic myringoplasty; R, retroauricular approach; MM, microscopic myringoplasty; M, male; F, female; GA, general anesthesia; ET, endoscopic tympanoplasty; MT, microscopic tympanoplasty; E, endaural approach; SD, standard deviation; NA, not available.

Table 2.
Hearing outcomes of 13 comparative studies between EES and MES
Study/country PTA calculation (frequency) EES vs. MES
Preoperative audiometry Postoperative audiometry Gain in ABG
Jyothi et al. (2017) [9]/lndia NA Mean ABG (dB): 34.16 vs. 35.54 Mean ABG (dB): 18 vs. 16 Mean improvement of ABGs (dB): 16.16 (SD, 4.68) vs. 19.54 (SD, 3.45)
Plodpai and Paje (2017) [10]/Thailand 0.5, 1, 2, and 4 kHz Median (range) ABG (dB): 25 (20-31) vs. 27 (16-30) Median (range) ABG (dB): 13(5-18) vs. 15(10-19) Median improvement of ABGs (dB)j 12 vs. 12
James (2017) [11]/Canada NA NA NA NA
Nassif et al. (2015) [12]/Italy 0.5, 1, 2, and 4 kHz Median ABG (dB): 16.6 vs. 19.4 Median ABG (dB): 6.6 vs. 6.2 Median improvement of ABGs (dB): 9.4 vs. 11.2
Harugop et al. (2008) [13]/lndia 0.5, 1, and 2 kHz ABG <10dB:0vs. 0 ABG <10 dB: 23 (46%) vs. 10(20%) NA
10dB<ABG<20dB: 20 (40%) vs. 20 (4%) 10 dB<ABG<20 dB: 22 (44%) vs. 35 (70%)
20 dB<ABG<30 dB: 28 (56%) vs. 30 (60%) 20 dB<ABG<30 dB: 5 (10%) vs. 5 (10%)
30 dB<ABG<40 dB: 2 (4%) vs. 0 30dB<ABG<40dB:0vs. 0
Lade et al. (2014) Bindia NA Mean ABG (dB): 28.5 (SD, 5.11) vs. 32.37 (SD, 5.80) Mean ABGs (dB): 18.13 (SD, 7.11) vs. 16.87 (SD, 6.84) Mean improvement of ABGs (dB): 10.37 (SD, 6.11) vs. 15.5 (SD, 6.32)
Raj and Meher (2001) [15]/lndia NA ABG <10 dB: 2(10%) vs. 2(10%) ABG <10 dB: 12(60%) vs. 11 (55%) ABG <10 dB: 14(70%) vs. 16 (80%)
10 dB<ABG<20 dB: 6 (30%) vs. 9 (45%) 10 dB<ABG<20 dB: 6 (30%) vs. 6 (30%) 10 dB<ABG<20 dB: 6 (30%) vs. 3 (15%)
20 dB<ABG<30 dB: 10 (50%) vs. 7 (35%) 20 dB<ABG<30 dB: 1 (5%) vs. 2 (10%) 20 dB<ABG<30 dB: 0 vs. 1 (5%)
30 dB<ABG<40 dB: 2 (10%) vs. 2 (10%) 30 dB<ABG<40 dB: 1 (5%) vs. 1 (5%) 30dB<ABG<40dB:0vs. 0
Lakpathi et al. (2016) [16]/lndia 0.5, 1, and 2 kHz ABG <10dB:0vs. 0 ABG <10dB: 14 (46%) vs. 7 (25%) NA
10dB<ABG<20dB: 12 (40%) vs. 12 (40%) 10 dB<ABG<20 dB: 13 (44%) vs. 19 (65%)
20 dB<ABG<30 dB: 15 (50%) vs. 18 (60%) 20 dB<ABG<30 dB: 3 (10%) vs. 3 (10%)
30 dB<ABG<40 dB: 3 (10%) vs. 0 30dB<ABG<40dB:0vs. 0
Kumar et al. (2015) [17]/lndia NA Mean ABG (dB): 30 vs. 31.53 Mean ABG (dB): 15 vs. 16.03 Mean improvement of ABGs (dB): 15.03 vs. 13.96
Dundar et al. (2014) [18]/Turkey 0.5, 1, 2, and 4 kHz Mean ABG (dB): 20.40 (SD, 4.33) vs. 21.34 (SD, 3.90) Mean ABG (dB): 8.12 (SD, 3.27) vs. 8.13 (SD, 2.43) Mean improvement of ABGs (dB): 12.3 (SD, 3.8) vs. 13.2 (SD, 3.2)
Kaya et al. (2017) [19]/Turkey 0.5, 1, 2, and 4 kHz Mean ABG (dB): 23.23 (SD, 6.79) vs. 24.89 (SD, 6.62) Mean ABG (dB): 13.75 (SD, 3.37) vs. 15.00 (SD, 4.64) Mean improvement of ABGs (dB): 9.48 (SD, 5.23) vs. 9.89 (SD, 2.79)
Huang et al. (2016) [20]/Taiwan 0.5, 1, and 2 kHz Mean ABG (dB): 21.6 (SD, 11.2) vs. 21.4 (SD, 10.6) Mean ABG (dB): 12.7 (SD, 8.8) vs. 13.1 (SD, 9.4) Mean improvement of ABGs (dB): 8.9 (SD, 10.0) vs. 8.3 (SD, 10.0)
Kuo and \Nu (2017) [24]ATaiwan 0.5, 1, and 2 kHz Mean ABG (dB): 22.48 vs. 26.7 Mean ABG (dB): 11.79 vs. 18.7 Mean improvement of ABGs (dB): 10.69 vs. 8

EES, endoscopic ear surgery; MES, microscopic ear surgery; PTA, pure tone audiometry; ABG, air-bone gap; NA, not available; SD, standard deviation.

REFERENCES

1. Tan HE, Santa Maria PL, Eikelboom RH, Anandacoomaraswamy KS, Atlas MD. Type I tympanoplasty meta-analysis: a single variable analysis. Otol Neurotol. 2016 Aug;37(7):838-46.
crossref pmid
2. Rizer FM. Overlay versus underlay tympanoplasty. Part II: the study. Laryngoscope. 1997 Dec;107(12 Pt 2):26-36.
crossref pmid
3. Mundra RK, Sinha R, Agrawal R. Tympanoplasty in subtotal perforation with graft supported by a slice of cartilage: a study with near 100 % results. Indian J Otolaryngol Head Neck Surg. 2013 Dec;65(Suppl 3):631-5.
crossref pmid pmc
4. Jumaily M, Franco J, Gallogly JA, Hentzelman JL, Costa DJ, Wild AP, et al. Butterfly cartilage tympanoplasty outcomes: a single-institution experience and literature review. Am J Otolaryngol. 2018 Jul-Aug;39(4):396-400.
crossref pmid
5. Kozin ED, Gulati S, Kaplan AB, Lehmann AE, Remenschneider AK, Landegger LD, et al. Systematic review of outcomes following observational and operative endoscopic middle ear surgery. Laryngoscope. 2015 May;125(5):1205-14.
crossref pmid
6. Migirov L, Shapira Y, Horowitz Z, Wolf M. Exclusive endoscopic ear surgery for acquired cholesteatoma: preliminary results. Otol Neurotol. 2011 Apr;32(3):433-6.
crossref pmid
7. Tarabichi M. Endoscopic middle ear surgery. Ann Otol Rhinol Laryngol. 1999 Jan;108(1):39-46.
crossref pmid
8. Furukawa T, Watanabe T, Ito T, Kubota T, Kakehata S. Feasibility and advantages of transcanal endoscopic myringoplasty. Otol Neurotol. 2014 Apr;35(4):e140-5.
crossref pmid
9. Jyothi AC, Shrikrishna BH, Kulkarni NH, Kumar A. Endoscopic myringoplasty versus microscopic myringoplasty in tubotympanic CSOM: a comparative study of 120 cases. Indian J Otolaryngol Head Neck Surg. 2017 Sep;69(3):357-62.
crossref pmid pmc pdf
10. Plodpai Y, Paje N. The outcomes of overlay myringoplasty: endoscopic versus microscopic approach. Am J Otolaryngol. 2017 Sep-Oct;38(5):542-6.
crossref pmid
11. James AL. Endoscope or microscope-guided pediatric tympanoplasty? Comparison of grafting technique and outcome. Laryngoscope. 2017 Nov;127(11):2659-64.
crossref pmid
12. Nassif N, Berlucchi M, Redaelli de Zinis LO. Tympanic membrane perforation in children: endoscopic type I tympanoplasty, a newly technique, is it worthwhile. Int J Pediatr Otorhinolaryngol. 2015 Nov;79(11):1860-4.
crossref pmid
13. Harugop AS, Mudhol RS, Godhi RA. A comparative study of endoscope assisted myringoplasty and micrsoscope assisted myringoplasty. Indian J Otolaryngol Head Neck Surg. 2008 Dec;60(4):298-302.
crossref pmid pmc
14. Lade H, Choudhary SR, Vashishth A. Endoscopic vs microscopic myringoplasty: a different perspective. Eur Arch Otorhinolaryngol. 2014 Jul;271(7):1897-902.
crossref pmid
15. Raj A, Meher R. Endoscopic transcanal myringoplasty: a study. Indian J Otolaryngol Head Neck Surg. 2001 Jan;53(1):47-9.
crossref pmid pmc pdf
16. Lakpathi G, Sudarshan Reddy L. Comparative study of endoscope assisted myringoplasty and microscopic myringoplasty. Indian J Otolaryngol Head Neck Surg. 2016 Jun;68(2):185-90.
crossref pmid pmc pdf
17. Kumar M, Kanaujia SK, Singh A. A comparative study of endoscopic myringoplasty vs conventional myringoplasty. Otorhinolaryngology Clinics. 2015;7(3):132-37.
crossref
18. Dundar R, Kulduk E, Soy FK, Aslan M, Hanci D, Muluk NB, et al. Endoscopic versus microscopic approach to type 1 tympanoplasty in children. Int J Pediatr Otorhinolaryngol. 2014 Jul;78(7):1084-9.
crossref pmid
19. Kaya I, Sezgin B, Sergin D, Ozturk A, Eraslan S, Gode S, et al. Endoscopic versus microscopic type 1 tympanoplasty in the same patients: a prospective randomized controlled trial. Eur Arch Otorhinolaryngol. 2017 Sep;274(9):3343-9.
crossref pmid pdf
20. Huang TY, Ho KY, Wang LF, Chien CY, Wang HM. A comparative study of endoscopic and microscopic approach type 1 tympanoplasty for simple chronic otitis media. J Int Adv Otol. 2016 Apr;12(1):28-31.
crossref pmid
21. Tseng CC, Lai MT, Wu CC, Yuan SP, Ding YF. Endoscopic transcanal myringoplasty for anterior perforations of the tympanic membrane. JAMA Otolaryngol Head Neck Surg. 2016 Nov;142(11):1088-93.
crossref pmid
22. Tseng CC, Lai MT, Wu CC, Yuan SP, Ding YF. Comparison of the efficacy of endoscopic tympanoplasty and microscopic tympanoplasty: a systematic review and meta-analysis. Laryngoscope. 2017 Aug;127(8):1890-6.
crossref pmid
23. Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gotzsche PC, Ioannidis JP, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. PLoS Med. 2009 Jul;6(7):e1000100.
crossref pmid pmc
24. Kuo CH, Wu HM. Comparison of endoscopic and microscopic tympanoplasty. Eur Arch Otorhinolaryngol. 2017 Jul;274(7):2727-32.
crossref pmid pdf
25. Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ. 2003 Sep;327(7414):557-60.
crossref pmid pmc
26. Vrabec JT, Deskin RW, Grady JJ. Meta-analysis of pediatric tympanoplasty. Arch Otolaryngol Head Neck Surg. 1999 May;125(5):530-4.
crossref pmid
27. Kozin ED, Lehmann A, Carter M, Hight E, Cohen M, Nakajima HH, et al. Thermal effects of endoscopy in a human temporal bone model: implications for endoscopic ear surgery. Laryngoscope. 2014 Aug;124(8):E332-9.
crossref pmid pmc
28. Nardone M, Sommerville R, Bowman J, Danesi G. Myringoplasty in simple chronic otitis media: critical analysis of long-term results in a 1,000-adult patient series. Otol Neurotol. 2012 Jan;33(1):48-53.
crossref pmid
29. Kakehata S, Futai K, Sasaki A, Shinkawa H. Endoscopic transtympanic tympanoplasty in the treatment of conductive hearing loss: early results. Otol Neurotol. 2006 Jan;27(1):14-9.
crossref pmid
30. Marchioni D, Grammatica A, Alicandri-Ciufelli M, Genovese E, Presutti L. Endoscopic cochlear implant procedure. Eur Arch Otorhinolaryngol. 2014 May;271(5):959-66.
crossref pmid
31. Choi N, Noh Y, Park W, Lee JJ, Yook S, Choi JE, et al. Comparison of endoscopic tympanoplasty to microscopic tympanoplasty. Clin Exp Otorhinolaryngol. 2017 Mar;10(1):44-9.
crossref pmid pdf
32. De Zinis LO, Berlucchi M, Nassif N. Double-handed endoscopic myringoplasty with a holding system in children: preliminary observations. Int J Pediatr Otorhinolaryngol. 2017 May;96:127-30.
crossref pmid
33. Nazarzadeh M, Bidel Z, Moghaddam A. Meta-analysis of diabetes mellitus and risk of hip fractures: small-study effect. Osteoporos Int. 2016 Jan;27(1):229-30.
crossref pmid pdf
34. Rucker G, Schwarzer G, Carpenter JR, Binder H, Schumacher M. Treatment-effect estimates adjusted for small-study effects via a limit meta-analysis. Biostatistics. 2011 Jan;12(1):122-42.
crossref pmid pdf
Editorial Office
Korean Society of Otorhinolaryngology-Head and Neck Surgery
103-307 Park Tower officetel, Yongsan-dong 5-ga, Yongsan-gu, Seoul 04385, Korea
TEL: +82-2-711-9091   FAX: +82-2-3487-6603   E-mail: editor.eceo@gmail.com
Copyright © Korean Society of Otorhinolaryngology-Head and Neck Surgery.                 Developed in M2PI
Close layer
prev next